FENSO 70
SECTIONMokuan 70
The 83 mm frame keeps the sightline slim while 5+9A+5 double glazing holds a 0.44 U-Factor and a 30 dB acoustic rating.
Profile series, wall thickness, glass build-up and five performance numbers decide almost everything. This guide walks through each one using the FenSo range — eight series from a 56.9 mm entry frame to a 317 mm five-rail panoramic door.
Each card shows the tested figures from the 2026 catalogue. Use the bars to compare within the range, then match the series to the opening rather than to the price list.
FENSO 70
SECTIONThe 83 mm frame keeps the sightline slim while 5+9A+5 double glazing holds a 0.44 U-Factor and a 30 dB acoustic rating.
FENSO 115
SECTION700 Pa water tightness and 0.5 m³/(m·h) air tightness make this the most weather-tight casement in the range, on a 2.0 mm wall.
FENSO 110
SECTIONIntegrated screen, 0.3 m³/(m·h) air tightness and 35 dB acoustic rating at a 1.4 mm wall that keeps the delivered cost sensible.
FENSO 113
SECTION6+27A+6 glazing on a 2.0 mm wall gives the widest air cavity in the casement range, with a 35 dB rating for street-facing rooms.
FENSO 58
SECTIONA 56.9 mm frame still reaches 700 Pa water tightness, so narrow reveals do not have to mean a weaker seal.
FENSO 150
SECTION2.2 mm walls carry the load of large sashes, and the 150 mm two-rail track keeps panels tracking straight for years.
FENSO T50
SECTION8+24A+8 glazing with 8.0 mm structural sections up to five rails, for openings that run the full length of a room.
FENSO 140
SECTIONThe 139.6 mm two-rail profile sits low in the floor, so the track reads as a line rather than a step.
The opening type sets the seal, the usable clear width and how much wall you lose. Most specification mistakes happen here — not in the glass or the finish.
| Tipo | How it works | Ventilazione | Space taken | Uso tipico | FenSo series |
|---|---|---|---|---|---|
| Casement, outward | Full ventilation, sash swings out | Alto | None inside the room | Exposed facades, tall windows | 115, 110, 113, 58 |
| Lifting window | Sash slides up and clears the sill | Alto | None — sash stays in plane | Bathrooms, kitchens, service counters | 70 |
| Sliding door | Panels slide past each other | Medium to high | Stack width per panel | Balconies, terraces, wide openings | 150, T50, 140 |
| Fixed glazing | No opening | Nessuno | Nessuno | Views, stairwells, clerestories | Any series, fixed frame |
| Tilt and turn | Tilts in for ventilation, swings in for cleaning | Alto | Sash arc inside | Upper floors, cold climates | 88 series (inward) |
Rule of thumb. If the opening is wider than it is tall, a slider gives you more clear width per panel. If it is taller than wide and faces weather, an outward casement seals better because the sash presses onto the gasket as wind load rises. Still choosing between frame materials? The FenSo window buying guide 2026 compares aluminium against uPVC, timber and steel on the same criteria.
Every FenSo frame is extruded from 6063-T5 aluminum alloy and finished with powder coating. The series number is the nominal frame width; the wall thickness is what actually carries the wind load.
A magnesium-silicon alloy chosen for extrudability and a clean anodised or powder-coated face. T5 temper gives enough stiffness for door leaves without becoming brittle in cold weather.
Measured on the structural wall of the profile. Residential windows commonly sit at 1.4–2.0 mm; heavy sliding leaves and panoramic spans go to 2.2 mm and above.
A polyamide strip separates the inner and outer aluminium, so heat does not travel straight through the frame. It is the reason a 0.32 U-Factor is reachable without triple glazing.
A cured polyester layer that resists chalking and handles coastal salt better than thin anodising. Specify a marine-grade pretreatment within one kilometre of the coast.
Every FenSo series carries a 3D section cut. Three things are worth reading before you compare prices: the wall thickness at the load-bearing face, the number of chambers between the outer and inner skin, and whether the glazing sits on a drained slope.



Check the wall, not the catalogue photo. A 1.4 mm profile and a 2.0 mm profile can look identical from the room. The section drawing is the only place the thickness is visible: measure it with a caliper at the hinge side before accepting delivery, and check that the drain slot in the lower frame is actually open.
Water tightness, air tightness, wind pressure resistance, sound insulation and U-Factor are tested independently. A window can be excellent on one and ordinary on another, so read them as a set.
Test pressure before water penetrates the inner face. 450 Pa suits sheltered openings; 700 Pa is for exposed facades and driving rain. The rating only holds if the sill is drained and the weep holes are clear.
Leakage per metre of joint per hour. Lower is better. The 0.3 group (110, 113, 58) is roughly fifteen times tighter than the 4.5 lifting window, which trades tightness for a clear sill.
Every series is tested to 5.0 kPa, about 2.4 kN/m² of face load. On tall buildings the limiting factor is usually the fixing to structure, not the profile itself.
A 5 dB gain is clearly audible — roughly halving perceived loudness. The 35 dB group pairs wider cavities (27A, 24A) with heavier glass, which is why street-facing rooms should not default to the cheapest build-up.
| Series | Tipo | Frame | Parete | Glazing | Water Pa | Air | Wind kPa | dB | U |
|---|---|---|---|---|---|---|---|---|---|
| 70 Mokuan | Lifting window | 83 mm | 1.5 mm | 5+9A+5 | 450 | 4.5 | 5.0 | 30 | 0.44 |
| 115 Tianjing | Casement, outward opening | 115 mm | 2.0 mm | 6+20A+5 | 700 | 0.5 | 5.0 | 30 | 0.44 |
| 110 High Opening | Casement with integrated screen | 110 mm | 1.4 mm | 5+20A+5 | 700 | 0.3 | 5.0 | 35 | 0.35 |
| 113 Gaoran | Casement with integrated screen | 111.5 mm | 2.0 mm | 6+27A+6 | 550 | 0.3 | 5.0 | 35 | 0.35 |
| 58 Chuanglan | Entry casement | 56.9 mm | 1.4 mm | 5+20A+5 | 700 | 0.3 | 5.0 | 30 | 0.35 |
| 150 Linghui | Heavy-duty sliding door | 150–225 mm | 2.2 mm | 6+20A+6 | 550 | 1.0 | 5.0 | 35 | 0.35 |
| T50 Lingye | Panoramic sliding door | 150–317 mm | 2.0 / 8.0 mm | 8+24A+8 | 550 | 1.0 | 5.0 | 35 | 0.35 |
| 140 Xizhe | Panoramic sliding door | 139.6–209 mm | 2.0–3.0 mm | 6+24A+6 | 550 | 1.0 | 5.0 | 35 | 0.35 |
How to read this table. Start from the water and air columns for the exposure, then use the U-Factor column to compare energy performance, and only then look at frame width. A wider frame is not automatically a better window — it is a deeper cavity, which helps only when the glass and seals are specified to match. If the opening size itself is still undecided, our standard window sizes 2026 reference lists common widths and heights in inches and millimetres.
The code reads as glass + cavity + glass. The number before the A is the pane thickness in millimetres, the number with the A is the air or argon cavity. A wider cavity improves both insulation and acoustics up to about 20 mm, then gains flatten.
| Build-up | Total mm | U-Factor | Ideale per | Used in |
|---|---|---|---|---|
| 5+9A+5 | 19 mm | 0.44 | Bathrooms, service windows, mild climates | 70 |
| 5+20A+5 | 30 mm | 0.35 | General residential, entry doors | 110, 58 |
| 6+20A+5 | 31 mm | 0.44 | Large casements on exposed walls | 115 |
| 6+20A+6 | 32 mm | 0.35 | Sliding doors with daily traffic | 150 |
| 6+24A+6 | 36 mm | 0.35 | Panoramic doors, wide living-room openings | 140 |
| 6+27A+6 | 39 mm | 0.35 | Street-facing rooms that need quiet | 113 |
| 8+24A+8 | 40 mm | 0.35 | Full-height glass walls, five-rail tracks | T50 |
Low-E coating on the room-side pane cuts radiant heat loss without visibly tinting the view. Laminated inner pane adds acoustic mass and holds glass in place if it breaks — the single best upgrade for a street-facing bedroom. Warm-edge spacer stops the perimeter of the glass from becoming the coldest surface, which is where condensation starts.
Triple glazing on a mild-climate south wall rarely returns its cost once the frame is already thermally broken. The same money spent on a 27 mm cavity, laminated glass and better seals delivers more quiet and less draught. Fix the installation before upgrading the glass.
Hinges, espagnolettes, rollers and gaskets decide whether the window still closes flush in year eight. FenSo specifies HOPO and Weirg Germany on the series where the sash weight demands it, and domestic hardware elsewhere.
A multi-point espagnolette system that pulls the sash onto the gasket at three or more points. On a 2.0 mm wall and a 115 mm frame, it is what holds the 700 Pa water rating under wind load.
Heavier hinge and locking hardware for wide or tall sashes. Specify it whenever a single leaf exceeds about 1.6 m² or carries laminated glass.
Proven hardware for standard sash weights. On sliding doors the rollers carry the panel, so check that they are adjustable and rated for the panel mass, not just the opening width.
A proper system has an outer weather seal, an inner air seal and a drained chamber between them. If the middle chamber is not drained, water that passes the first seal has nowhere to go but inward.
Door leaves carry different loads and use a different locking logic — the door buying guide 2026 walks through hinges, locks and security ratings for hinged, sliding and security doors.
Most site problems trace back to a dimension that was assumed rather than measured. Take these eight on every opening, and write them on the same drawing the factory will quote from.
Where an opening also takes a door leaf, dimensioni dell'apertura grezza per porte da 36 pollici explains the framing allowance and shim space in the same detail.
Frame is plumb, level and square within 2 mm over 2 m. Packers are at fixing points, not mid-span. Backer rod and sealant run continuously on both faces. Weep holes are open and facing out.
Every sash opens and closes with one hand. Espagnolette engages at all points without forcing. Sliding panels run without rocking and the rollers are adjusted so the panel sits parallel to the track.
Run a hose on the outside face for ten minutes at the worst joint, with the window closed. Check the inner reveal and the sill for moisture. Do this before the finish coat goes on.
No chipped edges, no scratched coating, drainage slots in the glazing bead clear. Labels removed and any adhesive residue cleaned with a neutral cleaner, never a solvent.
Adjustment window. Hardware settles in the first heating and cooling cycle. Book a return visit at four to six weeks to re-tension hinges and re-set rollers — it is the cheapest way to protect the ten-year life of the window.
It is the nominal frame width in millimetres measured across the profile. A 58 series frame occupies about 56.9 mm of wall depth, a 115 series about 115 mm. Wider series carry deeper glazing cavities and heavier sashes, which is why the number rises with span and wind load.
Not in isolation. 700 Pa is the top of the FenSo range and suits exposed facades, but it needs a properly drained sill and a continuous weather seal to mean anything. On a sheltered courtyard, a 550 Pa window installed correctly will outperform a 700 Pa window installed with a compressed gasket.
It is the leakage rate in m³ per metre of joint per hour. The 0.3 figure on the 110, 113 and 58 series means roughly one-fifteenth the leakage of a 4.5 rated frame, which shows up as less draught, less dust on the sill and a lower heating load.
0.44 versus 0.32 is about a 27 percent difference in conducted heat through the frame and glass. On a 20 m² glazed wall in a cold climate, that is a meaningful annual energy difference; in a mild climate the acoustic and water ratings usually matter more.
Yes, and it is common. Fixed panels can sit in a narrower frame while opening sashes use a deeper series for stiffness. Keep the sightline (the visible frame face) consistent so the elevation reads as one system.
The 110 and 113 are supplied as integrated screen windows — the screen tracks in the same frame, so it stays fitted all season without blocking the sash. The 115 and 58 are supplied without a screen unless specified.
1.4 mm is the common residential baseline. Go to 1.8–2.0 mm for openings over about 2.4 m high or in high-wind zones, and 2.2 mm or more for door leaves and wide sliding panels. The thickness is measured on the load-bearing wall of the profile, not the decorative face.
A typical apartment of eight to ten openings takes two to three days for installation plus one day for sealing and adjustment. Large panoramic doors take longer because the track has to be levelled and packed before the panels go in.
If you want the wider picture — casement, sliding, folding, louvre and curtain wall systems in one place — start from the FenSo windows and doors 2026 product guide.
Send us the eight measurements for each opening and we will return a schedule with the series, glass build-up and hardware that meets the exposure — with the tested figures attached.
Request a window schedule